| Measuring Range |
-50¢J -1300 ¢J ; -50 ¢K -1999 ¢K |
| Sensor |
K Type thermocouple |
| Input |
Single(1300), Dual (1302,1303) |
| Resolution |
-50¢J + 199.9¢J...0.1¢J
-50¢K + 199.9¢K...0.1¢K
(Others-1¢J/1¢K) |
| Accuracy: |
-50 ¢J to 199.9 ¢J ...0.3% rdg + 1 ¢J
-50 ¢K to 199.9 ¢K...0.3% rdg + 2 ¢K
-50 ¢J to 1000 ¢J ...0.5% rdg + 1 ¢J
-50 ¢K to 1999 ¢KF. ..0.5% rdg + 2 ¢K
1000 ¢J to 1300 ¢J ..0.75% rdg + 1 ¢J
(apply to mainframe only at 23 ¢J +/- 5 ¢J ) |
| Function |
H Data Hold & Display ¢J / o F selection
0.1 o /1 o resolution selection
T1 & T2 dual points display
T1 - T2 differential measurement
3-1/2 digit LCD |
| Temperature Coefficient |
Less than 0.1 time the applicable
accuracy specification per ¢J (¢K) |
| Overrange |
1------ |
| Low Battery |
BT |
| Temperature Coefficient |
Less than 0.1 time the applicable
accuracy specification per ¢J ( ¢K) |
| Input Protection |
60V DC or 24 Vrms AC maximum
input voltage on any combination of
input Connector.
Sampling Rate: 2.5 times/sec. |
| Operating Condition |
0 ¢J - 50 ¢J (32 ¢K-122 ¢K),
0-90% R.H. (0-35 ¢J ) |
| Power Source |
one 9V battery |
| Size Weight |
135mm(L)x72mm(W)x31mm(H) & 57g
Accessories: Battery & Instruction Manual |
| * OPTIONAL TEMPERATURE PROBES |
Model Range (Type K (CA)THERMOCOUPLE)
TP-K01 Bead -50 ¢J to 200 ¢J /-58 ¢K to 392 ¢K
General Purpose
TP-K02 Immersion -50 ¢J to 1000 ¢J /-58¢K to 1832 ¢K
Liquid or gels.
TP-K03 Surface -50 ¢J to 750 ¢J /-58¢K to 1382 ¢K |