TES- 3079 HVAC Trms Clamp Meter (1000A)

HVAC Application
  • Check current draw in motors and compressors.
  • Use MAX/MIN/Recording in the temperature mode to assess efficiency.
  • Test run/start capacitors.
  • Confirm low voltage control signals.
  • Measure flame safeguard device current draw.
  • Confirm power sources
  • Analyze temperature and power data with the aid of the time stamp.
  • Insulation test up to 100M.
Electrical Application
  • Check for energized circuits.
  • Balance loads.
  • Evaluate electrical contacts.
  • Capture motor in-rush current readings.
  • Determine peak power demand periods.
  • Verify line voltage stability.
  • Monitor motors and other loads for excess heat.
  • Check motor run/start capacitor values.
 
AC Current (50Hz to 400Hz) : Trms
Range
Resolution
Accuracy
Sensitivity
Overload Protection
99.99A
10mA
¡Ó2% ¡Ó20dgts (50,60Hz)
¡Ó4% ¡Ó20dgts (40~400Hz)
0.10A
1000A
999.99A
100mA
1.0A
AC Voltage (50Hz to 400Hz) : Trms
Range
Resolution
Accuracy
Sensitivity
Overload Protection
999.9mV
0.1mV
¡Ó1% ¡Ó20dgts (50,60Hz)
¡Ó1% ¡Ó20dgts (50,60Hz)
2.0mV
600V
9.999V
1mV
¡Ó1% ¡Ó20dgts (50,60Hz)
¡Ó2% ¡Ó20dgts (40~400Hz)
0.020V
99.99V
10mV
0.20V
600.0V
100mV
2V
Input impedance : 3M£[
Resistance (Continuity<40£[ on the 999.9£[ range)
Range
Resolution
Accuracy
Overload Protection
999.9£[
100m£[
1.0% ¡Ó10dgts
600V
9.999£[
1£[
99.99£[
10£[
999.9£[
100£[
M£[
Range
Resolution
Accuracy
Overload Protection
9.999M£[
1K£[
5% ¡Ó10dgts
600V
99.99M£[
10K£[
Diode (Continuity<40mV)
Range
Resolution
Accuracy
Overload Protection
2.000V
1mV
¡Ó2% ¡Ó1dgt
600V
TRUE Power : (PF>0.7 or £c<45 ¢X )
Range
Resolution
Accuracy
Overload Protection
60.00KW (<100A)
10W
¡Ó5%rdg ¡Ó20dgts
(50, 60Hz)
600VAC/
1000AAC
600.0KW (>100A)
100W
Frequency
Range
Resolution
Accuracy
Sensitivity
40Hz / 1KHz
0.1Hz
¡Ó0.5%rdg ¡Ó2dgts
ACV>0.2V, ACA>6A
£gA Trms : (AC+DC) (Burden Voltage : 5mV/£gA)
Range
Resolution
Accuracy
Sensitivity
Overload Protection
99.99£gA
10nA
¡Ó1% ¡Ó20dgts
0.20£gA
600V
999.9£gA
100nA
2.0£gA
DC Voltage
Range
Resolution
Accuracy
Sensitivity
Overload Protection
999.9mV
0.1mV
¡Ó1.0% ¡Ó20dgts
2.0mV
600V
9.999V
1mV
0.020V
99.99V
10mV
0.20V
600.0V
100mV
2V
Input impedance : 3M£[
Capacitance
Range
Resolution
Accuracy
Overload Protection
10.000£gF
1nF
1.5% ¡Ó5dgts
600V
100.00£gF
10nF
1000.0£gF
100nF
7000£gF
1£gF
2.5% ¡Ó15dgts
Temperature (K-Type thermocouple)
Range
Resolution
Accuracy
Overload Protection
-50¢J to 900¢J
0.1¢J
1% ¡Ó1¢J
30V AC or 60V DC
-58¢J to 1000¢K
0.1¢K
1% ¡Ó2¢K
Phase Angle : (50Hz, 60Hz)
Range
Resolution
Accuracy
Sensitivity
50Hz / 60Hz
0.1¢X
¡Ó3.0¢X
ACV>100V, ACA>10A
Apparent Power
Range
Resolution
Accuracy

Overload Protection

60.00KVA (<100A)
10VA
¡Ó2.5%rdg ¡Ó20dgts
600VAC/1000AAC
600.0KVA (>100A)
100VA

 


TES Electrical Electronic Corp.
  • Office: 7F, No. 31, Lane 513, Rui Guang Road, Neihu Dist., Taipei, Taiwan, R.O.C
  • TEL:886-2-2799-3660 FAX:886-2-2799-5099