A: General Measurement
|
| Range |
DC - 600V
AC - 400V/ 600V |
| Accuracy |
DC - 0.75% rdg + 2 dgts
AC - 1.2%rdg + 5dgts |
| Input Impedance |
10M£[ |
| Overload Protection |
DC 1000V & AC 750V |
|
| Range |
4KHz/40KHz |
| Accuracy |
0.5% rdg + 5dgts |
| Resolution |
0.1Hz/1Hz |
| Max Input Sensitivity |
5A/1V |
| Overload Protection |
800A/750V |
|
| Continuity beeper |
below 40 £[ |
| Accuracy
Max Open Circuit Voltage |
3.2V |
| Overload Protection |
660Vrms |
|
| Range |
4K £[ |
| Accuracy |
1% rdg + 5dgts |
| Resolution |
0.001K £[ |
| Max Open Circuit Voltage |
0.5VDC |
| Overload Protection |
660Vrms |
|
| Range |
400/600A |
| Accuracy |
2% rdg + 5 dgts |
| Resolution |
0.1/1A |
| Overload Protection |
800A |
|
| Resolution |
0.001V |
| Accuracy |
1% rdg + 2 dgts |
| Overload Protection |
660Vrms |
|
B: Peak Hold Measurement
|
| Range |
400/600A |
| Accuracy |
2% rdg + 10 dgts |
| Resolution |
0.1A/1A |
| Overload Protection |
800A |
|
| Range |
400/600V |
| Accuracy |
1.5% rdg + 10 dgts |
| Resolution |
0.1V/1V |
| Input Impedance |
10M £[ |
| Overload Protection |
DC 1000V & AC 750V |
|
Numerical Display:
3 3/4 digit liquid crystal display (LCD) maximum
reading 3999.
Sampling Rate: 2 times/sec
|
Power Source:
one 006p 9V or IEC 6F22 or NEDA 1604 Battery
Dimensions: 239(L) x 66(W) x 34(H) mm
Weight: Approx. 465g |