- 3 f 4W, 3 f 3W, 3 f Balanced, 1 f 2W, and 1 f 3W Power Measurement.
- AC+DC true power, and True RMS AC Voltage and Current
- AC+DC 2000A, AC 600V, DC 800V
- AC+DC 1200KW(1 f ), AC+DC 2000KW (3 f )
- Dual Display V+Hz, A+Hz, W+PF, KVA+KVAR, V+A
- Phase Angle Measurement
- 3 f RST(L1L2L3) Sequence Indication.
- Memory of 4 records.
- DCA/DCW Auto Zero when power clamp powering on.
- AC/DC Auto Detection.
- Auto range.
|
 |
|
| AC+DC True Power
(PF 0.2-1.0, 3
£X
3W, 3
£X
4W, 1
£X
2W, and 1
£X
3W) |
Range |
Resolution |
Accuracy(of rdg) |
Input Range |
0-99.9KW |
0.1KW |
+/- 2.0% +/- 0.05KW |
AC 600V, DC 800V, ACA/DCA 2000A |
100-999.9KW |
0.1KW |
+/- 2.0% +/- 0.5KW |
AC 600V, DC 800V, ACA/DCA 2000A |
1000-1200KW |
1KW |
+/- 2.0% +/- 5KW |
AC 600V, DC 800V, ACA/DCA 2000A |
|
| AC+DC True Power (Power Factor 0.2-1.0, 3 £X Balanced Power) |
Range |
Resolution |
Accuracy
(or rdg) |
Input Range |
0-99.99KW |
0.01KW |
+/- 2.0% +/- 0.5KW |
AC 600V, DC 800V, ACA/DCA 2000A |
100-999.9KW |
0.1KW |
+/- 2.0% +/- 0.5KW |
AC 600V, DC 800V, ACA/DCA 2000A |
1000-1200KW |
1KW |
+/- 2.0% +/- 5KW |
AC 600V, DC 800V, ACA/DCA 2000A |
POWER FACTOR (PF)
PF=KW/KVA
|
|
| AC+DC Voltage (True RMS, Crest Factor<4, Autorange,
Overload Protection 800VAC for all ranges) |
Range |
Resolution |
Accuracy(of reading) |
Input Impedance |
DC, 50/60Hz |
40-400Hz |
0-200A |
0.1V |
+/- 1.5% +/- 5 dgts |
+/- 2.0% +/- 5 dgts |
10M
£[
|
200-500A |
0.1V |
+/- 1.5% +/- 5 dgts |
+/- 2.0% +/- 5 dgts |
10M
£[
|
500-600VAC
500-800VDC |
1V |
+/- 1.5% +/- 5 dgts |
+/- 2.0% +/- 5 dgts |
10M
£[
|
|
| AC+DC Current (True RMS, Crest Factor<4) |
Range |
Resolution |
Accuracy(of reading) |
Overload Protection |
DC, 50/60 Hz |
40-400Hz |
0-200A |
0.1A |
+/- 1.5% +/- 5 dgts |
+/- 2.0% +/- 5 dgts |
AC 3000A |
200-500A |
0.1A |
+/- 2.0% +/- 5 dgts |
+/- 2.5% +/- 5 dgts |
AC 3000A |
500-2000A |
1A |
+/- 2.5% +/- 5 dgts |
+/- 3.0% +/- 5 dgts |
AC 3000A |
AC+DC KVA (Apparent Power)
(KVA)=VxA/1000
AC+DC KVAR (Reactive Power)
(KVAR)=
|
|
| Phase Angle (must zero current reading before measurement) |
Range |
Accuracy |
Sensitivity |
Remark |
50/60Hz |
+/- 2.0
¢X
|
V>100V, A>10A |
Zero Crossing Detection |
|
| Frequency (if<10 Hz, Hz=0) |
Range |
Accuracy |
Sensitivity |
50/60Hz |
+/- 2dgts |
V: >1V, A: >5A |
10-400Hz |
+/- 0.5% +/- 2dgts |
V: >1A, A: >5A |
|
| Conductor Size |
Cable f 55mm. (approx.)
Bus Bar 65mm(D)x24mm(W) |
| Battery Type |
9V |
| Display |
2x4 Digits Dual Display LCD |
| Range Selection |
Auto |
| Overload Indication |
OL |
| Power Consumption |
28mA (approx.) |
| Low battery Indication |
 |
| Sampling Time |
0.5 sec. (V and A)
1.6 sec. (W) |
| Operating Temperature |
4 o to 50 o C |
| Operating Humidity |
Less than 85% relative |
| Altitude |
up to 2000M |
| Storage Temperature |
-20 o C to 60 o |
| Storage Humidity |
Less than 75% relative |
| Dimensions |
271mm(L)x112mm(W)x46mm(H)
10.7"(L)x4.4"(W)x1.8"(H) |
| Weight |
647g/22.8 oz (Battery included) |
|
|
|