Over-Voltage , Over-Current Protection
- Built-in Buzzer Alarm
- Easy RECALL and STORE functions
- Stby / Operate Button
- English-like RS-232C commands
- OCP With Programmable Timer
- 200 Sets of Memory
- AUTO-STEP function with programmable interval
- Bi-direction RS-232C interface
- 3.8 kg / 8.4 Lbs weight
|
 |
|
| Programmed Voltage and Current (5 minutes after power on) |
|
Range |
Resolution |
Accuracy |
Comments |
Voltage V (C.V.) |
0 ¡V 40V |
1mV
|
0.05% ¡Ó 9mV |
Typical ¡Ó 5mV |
Current A (C.C.) |
0 ¡V5V |
1mA |
0.2% ¡Ó 9mA |
Typical ¡Ó 5mA |
| C.V.: Constant Voltage C.C.: Constant Current |
|
| Voltage and Current Readback |
|
Range |
Resolution |
Accuracy |
Voltage V (C.C.) |
0 ¡V 40V |
1mV
|
0.1% ¡Ó 12mV |
Current A (C.C.) |
0.05 ¡V5A |
1mA |
0.2% ¡Ó 12mA |
| C.V.: Constant Voltage C.C.: Constant Current |
|
| Load Regulation |
1mV¡þA |
| Line Regulation |
No effect if line voltage falls within 90V to 130V for 115V nominal, 200V to 240V for 230V nominal. |
| Fixed 5V / 2A Accuracy |
5V ¡Ó 0.25V |
| Fixed 3.3V / 3A Accuracy |
3.3V ¡Ó 0.16V |
: When 5V or 3.3V output is less than 1V (shorted), the corresponding symbol will be shown in LCD to warn the users. |
|
| Ripple and Noise (0 ~ 40V, 0 ~ 5A) |
<3mVrms (C.V.), typical 1mVrms |
| Ripple and Noise (0 ~ 40V, 0 ~ 5A) |
<3mArms (C.C.), typical 1mArms |
| Ripple and Noise (5V/2A, 3.3V/3A) |
10mVrms ~ 20mVrms, 10mArms ~20mArms |
| Temperature Coefficient |
< 100ppm/¢J |
| OCP Detection |
Current A > 0.05A |
| C.V. or C.C. Detect and Display |
Current > 0.05A |
| Power Source |
115V (90V to 130V) or 230V (200V to 240V) |
| Accessories |
power cord x 1, users manual x 1 |
| Dimensions |
310mm x 250mm x 133 mm / 12.2" x 9.8" x 5.2" |
| Weight |
3.8kg / 8.4lbs |
|
|
|
TES Electrical Electronic Corp. |
- Office: 7F, No. 31, Lane 513, Rui Guang Road,
Neihu Dist., Taipei, Taiwan, R.O.C.
- TEL:886-2-2799-3660 FAX:886-2-2799-5099
- E-Mail: tes@ms9.hinet.net
|
|