PROVA-901/903 Digital Multi-Meter

The DMM to replace your bench-top one

  • 0.02% DC and 0.1% AC basic accuracy
  • 60,000 counts resolution
  • 200KHz (max.) bandwidth
  • True RMS with fast ACV/ACA response
  • Dual channels measurement similar to a dual channels DSO (V+V, V+A)
  • RS-232C ASCII interface
  • Data logging (model 903 with 10,708 records for both channels)
  • Capacitance measurement
  • Free software (901,903)
  • 1/3 the cost
 
The following accuracy is specified for one single channel (channel 1 or channel 2). If dual channels are used at the same time, additional % of accuracy should be added to the listed accuracy. Please refer to the supplemental dual channels specification. The following accuracy is also specified for the ZEROED (relative) value. The accuracy is given as ¡Ó% of reading ¡Ó number of least significant digits.
Continuity : ( , open voltage 3V approx.)
Range
Resolution
Beeper
Overload Protection
999.99 £[
0.01 £[
< 40 £[ ( approx )
AC 1000V
Diode Test : (open voltage 3V approx.)
Range
Resolution
Short Circuit Current
Overload Protection
3.0000V
0.0001V
0.8 mA typical
AC 1000V
Frequency :
Range ( Auto )
Resolution
Accuracy
Overload Protection
1Hz - 200KHz( sine wave )
0.0001Hz -100Hz
¡Ó0.02%¡Ó4dgts
AC 1000V
1Hz -2MHz (TTL)
0.0001Hz - 0.0001MHz
¡Ó0.005%¡Ó4dgts
AC 1000V
Duty Cycle : (%, TTL, 1Hz ¡V 600KHz )
Range
Resolution
Accuracy
Overload Protection
0.001% - 9.999%
0.001%
¡Ó30d/KHz¡Ó30dgts
AC 1000V
10.00% - 100.00%
0.01%
¡Ó3d/KHz¡Ó3dgts
AC 1000V
Resistance: ( £[ )
Range
Resolution
Accuracy
Overload Protection
999.99 £[
0.01 £[
¡Ó0.15%¡Ó8dgts
AC 1000V
9.9999K £[
0.0001K £[
¡Ó0.09%¡Ó3dgts
AC 1000V
99.999K £[
0.001K £[

¡Ó0.09%¡Ó3dgts

AC 1000V
999.99K £[
0.01K £[
¡Ó0.09%¡Ó3dgts
AC 1000V
9.9999M £[
0.0001M £[
¡Ó0.2%¡Ó6dgts
AC 1000V
40.000M £[

0.001M £[

¡Ó1%¡Ó6dgts
AC 1000V
Capacitance: ( , auto range , and for film capacitor or better)
Range
Resolution
Accuracy 1
60.00nF
0.01nF
¡Ó0.8%¡Ó5dgts
600.0nF
0.1n F
¡Ó1.5%¡Ó5dgts
6.000 £g F
0.001 £g F
¡Ó1.5 %¡Ó5dgts
60.00 £g F
0.01 £g F
¡Ó2.0%¡Ó5dgts
600.0 £g F
0.1 £g F
¡Ó3.5%¡Ó5dgts
DC Voltage: (Input Impedance: 10M )
Range

Resolution

Accuracy
Overload Protection
60.000mV
0.001mV
¡Ó0.1%¡Ó5dgts 1
DC 1000V
600.00mV
0.01mV
¡Ó0.02%¡Ó3dgts
DC 1000V
6.0000V
0.0001V
¡Ó0.02%¡Ó3dgts
DC 1000V
60.000V

0.001V

¡Ó0.02%¡Ó3dgts
DC 1000V
600.00V
0.01V
¡Ó0.02%¡Ó3dgts
DC 1000V
1000.0V
0.1V
¡Ó0.04%¡Ó3dgts
DC 1000V

DC Current: (10A terminal is protected by a 10A fast blown, high energy fuse, and the terminal of £g A and mA is protected by 1A fast blown, high energy fuse )

Range

Resolution

Accuracy

600.00 £g A

0.01 £g A
¡Ó0.2%¡Ó10dgts
6000.0 £g A

0.1 £g A

¡Ó0.1%¡Ó10dgts
60.000mA
0.001mA
¡Ó0.2%¡Ó10dgts
600.00mA
0.01mA

¡Ó0.1%¡Ó10dgts

1.0000A
0.0001A
¡Ó0.1%¡Ó10dgts
10.000A 1
0.001A
¡Ó0.3%¡Ó10dgts

AC Current: (The accuracy is specified for a single channel for 5%-100% of range for 45Hz ¡V 20KHz, True RMS, 10A terminal is protected by a 10A fast blown, high energy fuse, and the terminal of £g A and mA is protected by 1A fast blown, high energy fuse )

Range (ACA)
Resolution
Accuracy (50/60Hz)
Accuracy (45Hz - 1KHz)
600.00 £g A
0.01m A
¡Ó0.3%¡Ó20dgts
¡Ó0.4%¡Ó20dgts
6000.0 £g A
0.1m A
¡Ó0.3%¡Ó20dgts
¡Ó0.4%¡Ó20dgts
60.000mA
0.001mA
¡Ó0.3%¡Ó20dgts
¡Ó0.4%¡Ó20dgts
600.00mA
0.01mA
¡Ó0.3%¡Ó20dgts
¡Ó0.4%¡Ó20dgts
1.0000A
0.0001A
¡Ó0.3%¡Ó20dgts
¡Ó0.4%¡Ó20dgts
10.000A 1
0.001A

¡Ó0.5%¡Ó20dgts

¡Ó0.4%¡Ó20dgts
 

Range

(ACA)

Accuracy

(20Hz - 45Hz)

Accuracy

(1KHz ¡V 10KHz)

Accuracy

(10KHz ¡V 20KHz)

600.00 £g A
¡Ó1%¡Ó20dgts
¡Ó2%¡Ó20dgts
¡Ó1%¡Ó20dgts
6000.0 £g A
¡Ó1%¡Ó20dgts
¡Ó2%¡Ó20dgts
¡Ó1%¡Ó20dgts
60.000mA
¡Ó1%¡Ó20dgts
¡Ó0.5%¡Ó20dgts
¡Ó1%¡Ó20dgts
600.00mA
¡Ó1%¡Ó20dgts
¡Ó0.5%¡Ó20dgts
¡Ó1%¡Ó20dgts
1.0000A
¡Ó1%¡Ó20dgts
¡Ó1.5%¡Ó20dgts
Not Specified
10.000A 1
¡Ó2%¡Ó20dgts
¡Ó1.5%¡Ó20dgts
Not Specified
AC Voltage: The accuracy of ACV or AC mV is specified for 5%-100% of range from 20Hz ¡V 10KHz, average sensing. Input Impedance is 10M , and overloaded protection is AC 1000V for all range. Accuracy is also specified for single channel (channel 1 or channel 2). If dual channels measurements are performed, additional specification of accuracy will be introduced. Please refer to the supplemental dual channels specification. Due to the wide bandwidth, the reading might not be zero when no inputs present. But the residual reading does not affect the listed accuracy. If the AC reading is less than 100 least significant counts, it is set to zero by the unit.

Range

(ACV)

Resolution

Accuracy

(50/60Hz)

Accuracy

(45Hz - 1KHz)

Accuracy

(20Hz - 45Hz)

60.000mV
0.001mV
¡Ó0.1%¡Ó20dgts
¡Ó0.3%¡Ó20dgts
¡Ó0.8%¡Ó25dgts
600.00mV
0.01mV
¡Ó0.1%¡Ó20dgts
¡Ó0.3%¡Ó20dgts
¡Ó0.8%¡Ó25dgts
6.0000V
0.0001V
¡Ó0.1%¡Ó20dgts
¡Ó0.3%¡Ó20dgts
¡Ó0.8%¡Ó25dgts
60.000V
0.001V
¡Ó0.1%¡Ó20dgts

¡Ó0.3%¡Ó20dgts

¡Ó0.8%¡Ó25dgts
600.00V
0.01V
¡Ó0.1%¡Ó20dgts
¡Ó0.5%¡Ó20dgts
¡Ó0.8%¡Ó25dgts

1000.0V

(0¡V400V)

0.1V

¡Ó0.1%¡Ó20dgts

¡Ó2%¡Ó30dgts

¡Ó0.8%¡Ó25dgts

1000.0V

(400-1000V)

0.1V

¡Ó0.1%¡Ó20dgts

(45Hz ¡V 400Hz)

¡Ó2%¡Ó30dgts

¡Ó0.8%¡Ó25dgts
 

Range

(ACV)

Accuracy

1KHz¡V10KHz)

Accuracy

(10KHz¡V20KHz)

Accuracy

(20KHz-50KHz)

Accuracy

(50KHz-100KHz)

Accuracy

(100kHz-200KHz)

60.000mV
¡Ó2%¡Ó20dgts
¡Ó2.5%¡Ó20dgts
¡Ó4%¡Ó40dgts
¡Ó4%¡Ó40dgts
Not Specified
600.00mV
¡Ó1%¡Ó20dgts
¡Ó2.5%¡Ó20dgts
¡Ó2%¡Ó40dgts
¡Ó2%¡Ó40dgts
¡Ó2%¡Ó40dgts
6.0000V
¡Ó1%¡Ó20dgts
¡Ó2.0%¡Ó20dgts
¡Ó2%¡Ó40dgts
¡Ó2%¡Ó40dgts
¡Ó2%¡Ó40dgts
60.000V
¡Ó1%¡Ó20dgts
¡Ó2.0%¡Ó20dgts
¡Ó4%¡Ó40dgts
Not Specified
Not Specified

600.00V

(0-400V)

¡Ó5%¡Ó20dgts
Not Specified
Not Specified
Not Specified
Not Specified

600.00V

(400-600V)

Not Specified
Not Specified
Not Specified
Not Specified
Not Specified

1000.0V

(0-400V)

¡Ó2%¡Ó40dgts
Not Specified
Not Specified
Not Specified
Not Specified

1000.0V

(400-1000V)
Not Specified
Not Specified
Not Specified
Not Specified
Not Specified
Supplemental Dual Channels Specification (DC ¡V 400Hz): The following accuracy should be added to all the listed accuracy if dual channels measurements are performed.
ACV (Ch2)
DCV (Ch2)
ACA (Ch2)
DCA (Ch2)
ACV (Ch1)

¡Ó1%¡Ó( V1 - V2 ) 200 PPM (Ch1, Ch2)

¡Ó0.5%¡Ó(V1 - V2) * 20 PPM (Ch1, Ch2)
¡Ó0.1 £g A / V( £g A,Ch2)
¡Ó1 £g A / V (mA,Ch2)
¡Ó0.2mA / V (A, Ch2)
¡Ó2mV / A (mV, Ch1)
¡Ó 5mV / A (V, Ch1)
¡Ó0.25% (Ch1, Ch2)
DCV (Ch1)
¡Ó0.5%¡Ó(V1 - V2) * 20 PPM (Ch1, Ch2)
¡Ó0.25% (Ch1,Ch2
¡Ó0.25% (Ch1, Ch2)
¡Ó0.25% (Ch1, Ch2)
General Specification
Battery Type 9V
Display 5 + 5 digits LCD with 30 segments bar graph
Range Selection auto and manual
Overload Indication OL
Power Consumption 6 mA ( approx )
Low battery Indication
Operating Temperature -10 C to 50 C
Operating Humidity

less than 85% relative

Altitude up to 2000M
Storage Temperature -20 C to 60 C
Storage Humidity less than 75% relative
Dimension 207mm(L) x 101mm (W) x 47mm (H)8.15" (L) x 4" (W) x 1.85" (H)
Weight 430g / 15.2oz (battery included)
Accessories
Users manual x 1
9V battery x 1
RS-232C interface cable

 


TES Electrical Electronic Corp.
  • Office: 7F, No. 31, Lane 513, Rui Guang Road, Neihu Dist., Taipei, Taiwan, R.O.C.
  • TEL:886-2-2799-3660 FAX:886-2-2799-5099
  • E-Mail: tes@ms9.hinet.net